Every bit a "rules of thumb" amps horsepower rating can exist estimated to

  • 115 volts motor - single-phase : 14 amps/hp
  • 230 volts motor - single-phase : 7 amps/hp
  • 230 volts motor - 3-phase : ii.5 amps/hp
  • 460 volts motor - 3-phase : ane.25 amps/hp

Always check nameplate information before designing protective devices, wiring and switch gear.

Electric motor

Single-Stage Motors - HP and Full-Load Currents

A motor of a given rated horsepower is expected to evangelize that quantity of mechanical power at the motor shaft. Be aware that the motor efficiency is not calculated in to the values for kW and amps below. Motor efficiency must be considered to avoid undersized power supply.

Power Full Load Current (amp)
(hp) (kW) 115 Five 208 V 230 V
1/six 0.13 iv.four 2.4 2.2
1/4 0.19 5.viii 3.2 ii.9
i/3 0.25 7.2 4.0 3.6
1/2 0.38 9.viii 5.4 4.9
3/4 0.56 13.eight 7.6 6.nine
one 0.75 16 8.8 8
1 1/two one.1 xx 11 x
2 1.5 24 thirteen.2 12
3 2.3 34 xviii.7 17
5 iii.8 56 30.8 28

Note that nigh electric motors are designed to run at 50% to 100% of rated load and that maximum efficiency commonly is virtually 75% of rated load. For a 1 horsepower (hp) motor the load should typically exist in the range 1/two to 1 hp with maximum efficiency at iii/four hp.

Typical load ranges:

  • acceptable for a short-menstruum: 20 - 120%
  • acceptable for operating: 50 - 100%
  • optimum efficiency: threescore - 80%

A motor with a service factor can occasional be overloaded. Overloading volition over time reduce motor efficiency.

3-Stage Motors - HP and Full-Load Currents

Power Full-Load Current (amp)
Consecration Type
Squirrel-Cage and Wound Motor
Synchronous Type
Unity Power Factor
(hp) (kW) 115 V 230 V 460 V 575 Five 2300 V 230 V 460 Five 575 V 2300 V
1/ii 0.38 4 2 1 0.8
3/4 0.56 v.6 ii.8 1.4 1.one
ane 0.75 vii.two three.6 one.8 ane.4
1 1/two 1.one 10.four five.2 two.half dozen 2.1
2 ane.5 13.half-dozen vi.8 3.4 ii.7
3 2.3 9.6 iv.8 three.ix
v 3.8 15.2 7.half-dozen 6.1
seven ane/2 5.six 22 11 ix
x 7.5 28 14 11
15 eleven 42 21 17
20 15 54 27 22
25 19 68 34 27 53 26 21
xxx 23 eighty 40 32 63 32 26
40 xxx 104 52 41 83 41 33
50 38 130 65 52 104 52 42
60 45 154 77 62 16 123 61 49 12
75 56 192 96 77 20 155 78 62 fifteen
100 75 248 124 99 26 202 101 81 xx
  • 1 hp (English language horse power) = 745.7 W = 0.746 kW = 550 ft lb/s = 2,545 Btu/h = 33.000 ft lb/m = 1.0139 metric equus caballus power ~= 1.0 KVA

Direct Electric current Motors - Power and Full Load Currents

Ability Direct Current (A)
(hp) (kW) 230 V 440 5
1/iv 0.nineteen 0.81 0.42
1/3 0.25 1.ane 0.56
1/2 0.37 1.half-dozen 0.85
3/4 0.56 2.4 1.three
1 0.75 3.ii 1.vii
1 1/ii ane.i 4.nine 2.v
2 1.5 vi.5 3.iv
3 2.2 9.seven v.1
5 three.7 16 8.v
vii 1/2 five.6 24 13
10 seven.v 32 17
15 11 49 25
20 fifteen 65 34
30 22 97 51
50 37 162 85
75 56 243 127
100 75 324 170
  • for 115V - the amps is twice the amps for 230V